MODELS
& OPERATION
The Pharma R&D Coater is available in 2 different models : Deluxe
and Super Deluxe. Depending on the machinery that already
exists at your coating facility, you can decide which model
suits your needs best. In the table below, "Y" indicates
that the component is available.
|
Particulars |
Deluxe |
Super Deluxe |
Pharma
R&D Coater Pan Size |
4"/
6"/ 8" |
4" / 6" / 8" |
|
Closed
Cabinet |
Peristaltic Pump (Control
solution spray rate) |
Y |
Y |
| Blower + Heater |
Y |
Y |
| Exhaust system |
Y |
Y |
|
Upper
Assembly |
Coating Drive Machine |
Y |
Y |
| Control Panel |
Y |
Y |
| a) Digital Temperature Indicator
& Controller |
Y |
Y |
| b) Digital Peristaltic Pump Indicator |
Y |
Y |
| c) Digital Pan RPM Indicator |
Y |
Y |
| d) Pan RPM Controller |
Y |
Y |
| e) Main Switch |
Y |
Y |
| f) Heater On/Off with indicator lamp |
Y |
Y |
| g) Blower On/Off with indicator lamp |
Y |
Y |
| h) Exhaust On/ Off with indicator
lamp |
Y |
Y |
| i) Coating Pan On/Off indicator lamp |
Y |
Y |
| Spray Gun |
Y |
Y |
| Spray Gun Stand |
Y |
Y |
| Exhaust Duct |
Y |
Y |
| Inlet Air Pipeline |
Y |
Y |
| Closed Cabinet for Pan |
N |
Y |
| PLC & SCAD
software |
N |
Y |
|
Optional |
Coating Pan Size |
12" |
12" |
OPERATION :
The Pharma R&D Coater is an integrated and automatic / semi-automatic
unit consisting of a stainless steel (304/316) coating pan, a spraying
system, a hot air blower, and an exhaust system. It uses the rotary
momentum of the coating pan to tumble the tablets / granules contained
with it. Baffles are provided along the interior walls of the pan
to tilt the contents for efficient coating.
As film coating requires a spray technique, a spray gun delivers
finely nebulized droplets of the coating solution onto the moving
tablet bed, in such a manner as to ensure uniform coverage. The tablets
are dried by directing a stream of hot air onto the surface of the
tablet bed and the exhaust system takes care of the unwanted solvent
vapours. The hot air blower maintains the temperature between 60°
- 80° C, to achieve better performance. All the settings, including
the temperature and rotation speeds, can be measured and adjusted
accurately using the advanced control panel. Feeding and retrieving
the tablets / granules from the pan should be done with a scoop, and
the various parameters for coating should be established through trial.
|